200-0404
$1.60*
Downloads
The memory cable...
Will get things in order. In switching cabinets and racks it often looks like on grandma's knitting pattern. Tidiness is indispensable. The SC-Isopod SO-F22 is a 2-wire, foil-shielded cable with a compact outer diameter of 3,30 mm. The cable is primarily used for the internal wiring in audio and hi-fi components. It has a “memory effect“ and can be laid “around the corner“ easily. The Cu wires of the individual wire pairs are already pre-stranded and very easy to strip. For a simpler assembly, the cable has an additional pre-stranded, tin-plated drain wire. It is shielded by an AL/PT foil that will automatically stick on the jacket when stripping it.
Advantages:
- Quick and easy to handle
- Robust plastic jacket for long life
- Easy to lay thanks to “memory effect”
Application:
- Internal wiring of racks, audio and hifi components
Article number: | 200-0404 |
---|---|
Name: | SC-Isopod SO-F22 |
EAN: | 4049371004527 |
Properties: | Analog, OFC oxygen free copper |
Application area: | Installation |
Application: | Patch cable |
Colour: | green |
Signal transmission: | symmetrical |
Construction: | (2LI2Y0,22mm²)(ST)Y |
Jacket material: | PVC |
Jacket Ø [mm]: | 3,30 |
Jacket Ø ["]: | 0.1299 |
Number of Channels (audio): | 1 |
Inner conductor (audio): | 2 |
Inner conductor (audio) [mm²]: | 0,22 |
Inner conductor (audio) [sqin]: | 0.0003 |
Inner conductor Ø (audio) [mm]: | 0,53 |
Inner conductor Ø (audio) ["]: | 0.0209 |
AWG (audio): | 24 |
Shielding: | AL / PT foil + AL / PT foil + filler strand, tin-plated |
Shielding factor [%]: | 100 |
Copper strands (audio): | 7 |
Copper strand Ø (audio) [mm]: | 0,20 |
Copper strand Ø (audio) ["]: | 0.0079 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,12 |
Conductor insulation Ø ["]: | 0.0441 |
Weight per 1 m [g]: | 16 |
Weight at 1000 ft. [lbs]: | 10.7667 |
Fire load per m [kWh]: | 0,05 |
Style variant: | round |
Packing: | 200 m spool |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 3,3 |
Width ["]: | 0.1299 |
Height [mm]: | 3,3 |
Height ["]: | 0.1299 |
Capac. cond./cond. per 1 m (audio) [pF]: | 74 |
Capacity wire/wire at 1 ft. (audio) [pF]: | 22.5552 |
Capac. cond./shield. per 1 m (audio) [pF]: | 143 |
Capacity wire/electic screen at 1 ft. (audio) [pF]: | 43.5864 |
Insulation resist. per 1 km [GΩ]: | 0,2 |
Insulation resist. per 1000 feet [GΩ]: | 0.061 |
Insulation resist. per 1 km (audio) [GΩ]: | 0,2 |
Insulation resist. per 1000 feet (audio) [GΩ]: | 0.061 |
Conductor resistance per 1 km [Ω]: | 88 |
Conductor resistance per 1000 ft. [Ω]: | 26.8224 |
Shield. resistance per 1 km [Ω]: | 75 |
Shield. resistance per 1000 ft. [Ω]: | 22.86 |
BPVo-Euroclass: | Fca |
Article number: | 200-0404 |
---|---|
Name: | SC-Isopod SO-F22 |
EAN: | 4049371004527 |
Properties: | Analog, OFC oxygen free copper |
Application area: | Installation |
Application: | Patch cable |
Colour: | green |
Signal transmission: | symmetrical |
Construction: | (2LI2Y0,22mm²)(ST)Y |
Jacket material: | PVC |
Jacket Ø [mm]: | 3,30 |
Jacket Ø ["]: | 0.1299 |
Number of Channels (audio): | 1 |
Inner conductor (audio): | 2 |
Inner conductor (audio) [mm²]: | 0,22 |
Inner conductor (audio) [sqin]: | 0.0003 |
Inner conductor Ø (audio) [mm]: | 0,53 |
Inner conductor Ø (audio) ["]: | 0.0209 |
AWG (audio): | 24 |
Shielding: | AL / PT foil + AL / PT foil + filler strand, tin-plated |
Shielding factor [%]: | 100 |
Copper strands (audio): | 7 |
Copper strand Ø (audio) [mm]: | 0,20 |
Copper strand Ø (audio) ["]: | 0.0079 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,12 |
Conductor insulation Ø ["]: | 0.0441 |
Weight per 1 m [g]: | 16 |
Weight at 1000 ft. [lbs]: | 10.7667 |
Fire load per m [kWh]: | 0,05 |
Style variant: | round |
Packing: | 200 m spool |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 3,3 |
Width ["]: | 0.1299 |
Height [mm]: | 3,3 |
Height ["]: | 0.1299 |
Capac. cond./cond. per 1 m (audio) [pF]: | 74 |
Capacity wire/wire at 1 ft. (audio) [pF]: | 22.5552 |
Capac. cond./shield. per 1 m (audio) [pF]: | 143 |
Capacity wire/electic screen at 1 ft. (audio) [pF]: | 43.5864 |
Insulation resist. per 1 km [GΩ]: | 0,2 |
Insulation resist. per 1000 feet [GΩ]: | 0.061 |
Insulation resist. per 1 km (audio) [GΩ]: | 0,2 |
Insulation resist. per 1000 feet (audio) [GΩ]: | 0.061 |
Conductor resistance per 1 km [Ω]: | 88 |
Conductor resistance per 1000 ft. [Ω]: | 26.8224 |
Shield. resistance per 1 km [Ω]: | 75 |
Shield. resistance per 1000 ft. [Ω]: | 22.86 |
BPVo-Euroclass: | Fca |
SC-Isopod SO-F22
Patch cable
Advantages:
- Quick and easy to handle
- Robust plastic jacket for long life
- Easy to lay thanks to “memory effect”
Application:
- Internal wiring of racks, audio and hifi components
Technical Data:
- Article number: 200-0404
- Name: SC-Isopod SO-F22
- EAN: 4049371004527
- Properties: OFC oxygen free copper
- Properties: Analog
- Application area: Installation
- Application: Patch cable
- Colour: green
- Signal transmission: symmetrical
- Construction: (2LI2Y0,22mm²)(ST)Y
- Jacket material: PVC
- Jacket Ø: 3,30 mm
- Jacket Ø: 0.1299 "
- Number of Channels (audio): 1
- Inner conductor (audio): 2
- Inner conductor (audio): 0,22 mm²
- Inner conductor (audio): 0.0003 sqin
- Inner conductor Ø (audio): 0,53 mm
- Inner conductor Ø (audio): 0.0209 "
- AWG (audio): 24
- Shielding: AL / PT foil + AL / PT foil + filler strand, tin-plated
- Shielding factor: 100 %
- Copper strands (audio): 7
- Copper strand Ø (audio): 0,20 mm
- Copper strand Ø (audio): 0.0079 "
- Conductor insulation material: PE
- Conductor insulation Ø: 1,12 mm
- Conductor insulation Ø: 0.0441 "
- Weight per 1 m: 16 g
- Weight at 1000 ft.: 10.7667 lbs
- Fire load per m: 0,05 kWh
- Style variant: round
- Packing: 200 m spool
- Temperature min.: -25 °C
- Temperature max.: 70 °C
- Width: 3,3 mm
- Width: 0.1299 "
- Height: 3,3 mm
- Height: 0.1299 "
- Capac. cond./cond. per 1 m (audio): 74 pF
- Capacity wire/wire at 1 ft. (audio): 22.5552 pF
- Capac. cond./shield. per 1 m (audio): 143 pF
- Capacity wire/electic screen at 1 ft. (audio): 43.5864 pF
- Insulation resist. per 1 km: 0,2 GΩ
- Insulation resist. per 1000 feet: 0.061 GΩ
- Insulation resist. per 1 km (audio): 0,2 GΩ
- Insulation resist. per 1000 feet (audio): 0.061 GΩ
- Conductor resistance per 1 km: 88 Ω
- Conductor resistance per 1000 ft.: 26.8224 Ω
- Shield. resistance per 1 km: 75 Ω
- Shield. resistance per 1000 ft.: 22.86 Ω
- BPVo-Euroclass: Fca