500-0151-1
€20.02*
Downloads
Cable abuse without punishment...
This combi line contains one CAT-cable in combination with a power cable. The SC-MONOCAT POWER Series is equally suitable for permanent installations and mobile applications.
Advantages:
- LAN signal transmission incl. mains supply in one cable
- LAN cable also usable as an additional control line
Application:
- Mobile applications
Article number: | 500-0151-1 |
---|---|
Name: | SC-Monocat 110C |
EAN: | 4049371050975 |
Properties: | Analog, Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
Application: | hybrid cable |
Colour: | black |
Construction: | [(3LIY3x2,5mm²)Y+1x(4x(2LI2Yx0,14mm²))(ST)CY]Y |
Construction (power): | [(3LIY3x2,5mm²)Y |
Construction (network): | 1x(4x(2LI2Yx0,14mm²))(ST)CY]Y |
Jacket material: | PVC |
Jacket Ø [mm]: | 13,80 |
Jacket Ø ["]: | 0.5433 |
Inner conductor (power): | 3 |
Inner conductor (network): | 8 |
Inner conductor (power) [mm²]: | 2,50 |
Inner conductor (power) [sqin]: | 0.0039 |
Inner conductor (network) [sqin]: | 0.0002 |
Inner conductor (network) [mm²]: | 0,14 |
Shielding (network): | AL / PT-foil + Copper braiding tin-plated |
Shielding factor [%]: | 100 |
Copper strands (network): | 7 |
Copper strand Ø (network) [mm]: | 0,16 |
Copper strand Ø (network) ["]: | 0.0063 |
Conductor insulation material: | Foam / Skin-PE |
Weight per 1 m [g]: | 260 |
Weight at 1000 ft. [lbs]: | 170.9207 |
UV-resistant: | yes |
Fire load per m [kWh]: | 1,1 |
Style variant: | round |
Packing: | bulk stock |
CAT-Type: | CAT.7 |
Max. section length [m]: | 100 |
Max. section length [ft]: | 328.084 |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 13,8 |
Width ["]: | 0.5433 |
Height [mm]: | 13,8 |
Height ["]: | 0.5433 |
Capacity wire/wire at 1m (network) [pF]: | 44 |
Capacity wire/wire at 1 ft. (network) [pF]: | 13.4112 |
Impedance (network) [Ω]: | 100 |
Insulation resist. per 1km (power) [GΩ]: | 5 |
Insulation resist. per 1000 feet (power) [GΩ]: | 1.524 |
Test voltage [V]: | 2000 |
Nominal voltage (power) [V]: | 500 |
Operating voltage (power) [V]: | 300 |
BPVo-Euroclass: | Fca |
Article number: | 500-0151-1 |
---|---|
Name: | SC-Monocat 110C |
EAN: | 4049371050975 |
Properties: | Analog, Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
Application: | hybrid cable |
Colour: | black |
Construction: | [(3LIY3x2,5mm²)Y+1x(4x(2LI2Yx0,14mm²))(ST)CY]Y |
Construction (power): | [(3LIY3x2,5mm²)Y |
Construction (network): | 1x(4x(2LI2Yx0,14mm²))(ST)CY]Y |
Jacket material: | PVC |
Jacket Ø [mm]: | 13,80 |
Jacket Ø ["]: | 0.5433 |
Inner conductor (power): | 3 |
Inner conductor (network): | 8 |
Inner conductor (power) [mm²]: | 2,50 |
Inner conductor (power) [sqin]: | 0.0039 |
Inner conductor (network) [sqin]: | 0.0002 |
Inner conductor (network) [mm²]: | 0,14 |
Shielding (network): | AL / PT-foil + Copper braiding tin-plated |
Shielding factor [%]: | 100 |
Copper strands (network): | 7 |
Copper strand Ø (network) [mm]: | 0,16 |
Copper strand Ø (network) ["]: | 0.0063 |
Conductor insulation material: | Foam / Skin-PE |
Weight per 1 m [g]: | 260 |
Weight at 1000 ft. [lbs]: | 170.9207 |
UV-resistant: | yes |
Fire load per m [kWh]: | 1,1 |
Style variant: | round |
Packing: | bulk stock |
CAT-Type: | CAT.7 |
Max. section length [m]: | 100 |
Max. section length [ft]: | 328.084 |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 13,8 |
Width ["]: | 0.5433 |
Height [mm]: | 13,8 |
Height ["]: | 0.5433 |
Capacity wire/wire at 1m (network) [pF]: | 44 |
Capacity wire/wire at 1 ft. (network) [pF]: | 13.4112 |
Impedance (network) [Ω]: | 100 |
Insulation resist. per 1km (power) [GΩ]: | 5 |
Insulation resist. per 1000 feet (power) [GΩ]: | 1.524 |
Test voltage [V]: | 2000 |
Nominal voltage (power) [V]: | 500 |
Operating voltage (power) [V]: | 300 |
BPVo-Euroclass: | Fca |
SC-Monocat 110C
hybrid cable
Advantages:
- LAN signal transmission incl. mains supply in one cable
- LAN cable also usable as an additional control line
Application:
- Mobile applications
Technical Data:
- Article number: 500-0151-1
- Name: SC-Monocat 110C
- EAN: 4049371050975
- Properties: Analog
- Properties: Digital 110 Ω AES / EBU
- Properties: OFC oxygen free copper
- Application area: Stage / live
- Application area: Studio / Broadcast
- Application area: Mobile outdoor / indoor
- Application area: Installation
- Application: hybrid cable
- Colour: black
- Construction: [(3LIY3x2,5mm²)Y+1x(4x(2LI2Yx0,14mm²))(ST)CY]Y
- Construction (power): [(3LIY3x2,5mm²)Y
- Construction (network): 1x(4x(2LI2Yx0,14mm²))(ST)CY]Y
- Jacket material: PVC
- Jacket Ø: 13,80 mm
- Jacket Ø: 0.5433 "
- Inner conductor (power): 3
- Inner conductor (network): 8
- Inner conductor (power): 2,50 mm²
- Inner conductor (power): 0.0039 sqin
- Inner conductor (network): 0.0002 sqin
- Inner conductor (network): 0,14 mm²
- Shielding (network): AL / PT-foil + Copper braiding tin-plated
- Shielding factor: 100 %
- Copper strands (network): 7
- Copper strand Ø (network): 0,16 mm
- Copper strand Ø (network): 0.0063 "
- Conductor insulation material: Foam / Skin-PE
- Weight per 1 m: 254 g
- Weight at 1000 ft.: 170.9207 lbs
- UV-resistant: yes
- Fire load per m: 1,1 kWh
- Style variant: round
- Packing: bulk stock
- CAT-Type: CAT.7
- Max. section length: 100 m
- Max. section length: 328.084 ft
- Temperature min.: -25 °C
- Temperature max.: 70 °C
- Width: 13,8 mm
- Width: 0.5433 "
- Height: 13,8 mm
- Height: 0.5433 "
- Capacity wire/wire at 1m (network): 44 pF
- Capacity wire/wire at 1 ft. (network): 13.4112 pF
- Impedance (network): 100 Ω
- Insulation resist. per 1km (power): 5 GΩ
- Insulation resist. per 1000 feet (power): 1.524 GΩ
- Test voltage: 2000 V
- Nominal voltage (power): 500 V
- Operating voltage (power): 300 V
- BPVo-Euroclass: Fca