200-0051
€2.86*
Downloads
No blood running through those veins...
but yet a whole lot of life. A wire gauge of 2 x 0,34 mm² is impressive and the electrical data speaks for itself. A cable that provides great performance data at an excellent price, used for stage and studio settings. The large cross section and the low capacitance guarantee outstanding transmission quality, even over longer distances. The shielding, made of bare copper wires has a 95 % optical coverage (instead of the usual 85 %). The robust, rubberlike, matt outer sleeve is preferred by performing musicians and guarantees outstanding flexibility even in lowest temperatures.
Advantages:
- High transmission quality through the use of oxygen-free copper stranding with a large wire gauge of 2 x0,34 mm²
- Very low capacitance due to PE insulation
- Good shielding due to the dense Cu mesh screen
- High flexibility makes it easy to reel
Application:
- Stage application
- Studio operation
- Permanent Installation
Article number: | 200-0051 |
---|---|
Name: | Club Series MKII |
EAN: | 4049371001915 |
Properties: | Analog, OFC oxygen free copper |
Application area: | ELA 100 V, Installation, Stage / live, Studio / Broadcast |
Application: | Microphone Cable |
Colour: | black |
Signal transmission: | symmetrical |
Construction: | (2LI2Y0,34mm²)CY |
Jacket material: | PVC |
Jacket Ø [mm]: | 6.50 |
Jacket Ø ["]: | 0.2559 |
Number of Channels (audio): | 1 |
Inner conductor (audio): | 2 |
Inner conductor (audio) [mm²]: | 0,34 |
Inner conductor (audio) [sqin]: | 0.0005 |
Inner conductor Ø (audio) [mm]: | 0,66 |
Inner conductor Ø (audio) ["]: | 0.026 |
AWG (audio): | 22 |
Shielding: | Copper braided shielding with 0.10 mm indiv. strands |
Shielding factor [%]: | 95 |
Copper strands (audio): | 19 |
Copper strand Ø (audio) [mm]: | 0,15 |
Copper strand Ø (audio) ["]: | 0.0059 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,50 |
Conductor insulation Ø ["]: | 0.0591 |
Weight per 1 m [g]: | 51 |
Weight at 1000 ft. [lbs]: | 33.6458 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,22 |
Style variant: | round |
Packing: | 100 m spool, 500 m spool |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 6,5 |
Width ["]: | 0.2559 |
Height [mm]: | 6,5 |
Height ["]: | 0.2559 |
Capac. cond./cond. per 1 m (audio) [pF]: | 58 |
Capacity wire/wire at 1 ft. (audio) [pF]: | 17.6784 |
Capac. cond./shield. per 1 m (audio) [pF]: | 115 |
Capacity wire/electic screen at 1 ft. (audio) [pF]: | 35.052 |
Impedance [Ω]: | 100 |
Insulation resist. per 1 km [GΩ]: | 1 |
Insulation resist. per 1000 feet [GΩ]: | 0.3048 |
Insulation resist. per 1 km (audio) [GΩ]: | 1 |
Insulation resist. per 1000 feet (audio) [GΩ]: | 0.3048 |
Conductor resistance per 1 km [Ω]: | 55 |
Conductor resistance per 1000 ft. [Ω]: | 16.764 |
Shield. resistance per 1 km [Ω]: | 25 |
Shield. resistance per 1000 ft. [Ω]: | 7.62 |
BPVo-Euroclass: | Fca |
Article number: | 200-0051 |
---|---|
Name: | Club Series MKII |
EAN: | 4049371001915 |
Properties: | Analog, OFC oxygen free copper |
Application area: | ELA 100 V, Installation, Stage / live, Studio / Broadcast |
Application: | Microphone Cable |
Colour: | black |
Signal transmission: | symmetrical |
Construction: | (2LI2Y0,34mm²)CY |
Jacket material: | PVC |
Jacket Ø [mm]: | 6.50 |
Jacket Ø ["]: | 0.2559 |
Number of Channels (audio): | 1 |
Inner conductor (audio): | 2 |
Inner conductor (audio) [mm²]: | 0,34 |
Inner conductor (audio) [sqin]: | 0.0005 |
Inner conductor Ø (audio) [mm]: | 0,66 |
Inner conductor Ø (audio) ["]: | 0.026 |
AWG (audio): | 22 |
Shielding: | Copper braided shielding with 0.10 mm indiv. strands |
Shielding factor [%]: | 95 |
Copper strands (audio): | 19 |
Copper strand Ø (audio) [mm]: | 0,15 |
Copper strand Ø (audio) ["]: | 0.0059 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,50 |
Conductor insulation Ø ["]: | 0.0591 |
Weight per 1 m [g]: | 51 |
Weight at 1000 ft. [lbs]: | 33.6458 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,22 |
Style variant: | round |
Packing: | 100 m spool, 500 m spool |
Temperature min. [°C]: | -25 |
Temperature max. [°C]: | 70 |
Width [mm]: | 6,5 |
Width ["]: | 0.2559 |
Height [mm]: | 6,5 |
Height ["]: | 0.2559 |
Capac. cond./cond. per 1 m (audio) [pF]: | 58 |
Capacity wire/wire at 1 ft. (audio) [pF]: | 17.6784 |
Capac. cond./shield. per 1 m (audio) [pF]: | 115 |
Capacity wire/electic screen at 1 ft. (audio) [pF]: | 35.052 |
Impedance [Ω]: | 100 |
Insulation resist. per 1 km [GΩ]: | 1 |
Insulation resist. per 1000 feet [GΩ]: | 0.3048 |
Insulation resist. per 1 km (audio) [GΩ]: | 1 |
Insulation resist. per 1000 feet (audio) [GΩ]: | 0.3048 |
Conductor resistance per 1 km [Ω]: | 55 |
Conductor resistance per 1000 ft. [Ω]: | 16.764 |
Shield. resistance per 1 km [Ω]: | 25 |
Shield. resistance per 1000 ft. [Ω]: | 7.62 |
BPVo-Euroclass: | Fca |
Club Series MKII
Microphone Cable
Advantages:
- High transmission quality through the use of oxygen-free copper stranding with a large wire gauge of 2 x0,34 mm²
- Very low capacitance due to PE insulation
- Good shielding due to the dense Cu mesh screen
- High flexibility makes it easy to reel
Application:
- Stage application
- Studio operation
- Permanent Installation
Technical Data:
- Article number: 200-0051
- Name: Club Series MKII
- EAN: 4049371001915
- Properties: Analog
- Properties: OFC oxygen free copper
- Application area: Stage / live
- Application area: Studio / Broadcast
- Application area: Installation
- Application area: ELA 100 V
- Application: Microphone Cable
- Colour: black
- Signal transmission: symmetrical
- Construction: (2LI2Y0,34mm²)CY
- Jacket material: PVC
- Jacket Ø: 6,50 mm
- Jacket Ø: 0.2559 "
- Number of Channels (audio): 1
- Inner conductor (audio): 2
- Inner conductor (audio): 0,34 mm²
- Inner conductor (audio): 0.0005 sqin
- Inner conductor Ø (audio): 0,66 mm
- Inner conductor Ø (audio): 0.026 "
- AWG (audio): 22
- Shielding: Copper braided shielding with 0.10 mm indiv. strands
- Shielding factor: 95 %
- Copper strands (audio): 19
- Copper strand Ø (audio): 0,15 mm
- Copper strand Ø (audio): 0.0059 "
- Conductor insulation material: PE
- Conductor insulation Ø: 1,50 mm
- Conductor insulation Ø: 0.0591 "
- Weight per 1 m: 50 g
- Weight at 1000 ft.: 33.6458 lbs
- UV-resistant: yes
- Fire load per m: 0,22 kWh
- Style variant: round
- Packing: 100 m spool
- Packing: 500 m spool
- Temperature min.: -25 °C
- Temperature max.: 70 °C
- Width: 6,5 mm
- Width: 0.2559 "
- Height: 6,5 mm
- Height: 0.2559 "
- Capac. cond./cond. per 1 m (audio): 58 pF
- Capacity wire/wire at 1 ft. (audio): 17.6784 pF
- Capac. cond./shield. per 1 m (audio): 115 pF
- Capacity wire/electic screen at 1 ft. (audio): 35.052 pF
- Impedance: 100 Ω
- Insulation resist. per 1 km: 1 GΩ
- Insulation resist. per 1000 feet: 0.3048 GΩ
- Insulation resist. per 1 km (audio): 1 GΩ
- Insulation resist. per 1000 feet (audio): 0.3048 GΩ
- Conductor resistance per 1 km: 55 Ω
- Conductor resistance per 1000 ft.: 16.764 Ω
- Shield. resistance per 1 km: 25 Ω
- Shield. resistance per 1000 ft.: 7.62 Ω
- BPVo-Euroclass: Fca