540-0051FC
€6.15*
Downloads
One step forward, one step back...
Round and round, this ain't too hard. When data have to pass to and fro, a digital cable with return channel should be used. The wave impedance is also defined as 110 Ω with this cable. Of the 4 wires 2 are employed for the feedback function. The robust outer jacket is suitable for outdoor and fixed installations alike. Color coding according to DIN 47100. Owing to the double shielding (AL/PT foil + Cu braid) and the wire coding it complies with the generally applicable regulations (VDE 0812/VDE 0207). Transfer speed 256 Kbs pursuant to EIA 485 standard.
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
- Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
Article number: | 540-0051FC |
---|---|
Name: | Binary 434 DMX512 |
EAN: | 4049371410731 |
Properties: | Analog, Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | ELA 100 V, Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
Application: | DMX |
Colour: | black |
Signal transmission: | symmetrical |
Construction: | [2(2LI2YS0,34mm²)(ST)]CY |
Jacket material: | FRNC |
Jacket Ø [mm]: | 7.00 |
Jacket Ø ["]: | 0.2756 |
Number of Channels (AES/EBU, DMX): | 1 |
Inner conductor (AES/EBU, DMX): | 4 |
Inner conductor (AES/EBU, DMX) [mm²]: | 0,34 |
Inner conductor (AES/EBU, DMX) [sqin]: | 0.0005 |
Inner conductor Ø (AES/EBU, DMX) [mm]: | 0,66 |
Inner conductor Ø (AES/EBU, DMX) ["]: | 0.026 |
AWG (AES/EBU, DMX): | 22 |
Shielding: | Copper-cross mesh, tined + AL / PT foil |
Shielding factor [%]: | 100 |
Copper strands (AES/EBU, DMX): | 7 |
Copper strand Ø (AES/EBU, DMX) [mm]: | 0,25 |
Copper strand Ø (AES/EBU, DMX) ["]: | 0.0098 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,70 |
Conductor insulation Ø ["]: | 0.0669 |
Weight per 1 m [g]: | 65 |
Weight at 1000 ft. [lbs]: | 43.7395 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,22 |
Style variant: | round |
Packing: | 100 m spool |
Temperature min. [°C]: | -15 |
Temperature max. [°C]: | 80 |
Width [mm]: | 7 |
Width ["]: | 0.2756 |
Height [mm]: | 7 |
Height ["]: | 0.2756 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF]: | 58 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF]: | 17.6784 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF]: | 100 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF]: | 30.48 |
Impedance [Ω]: | 110 |
Insulation resist. per 1 km [GΩ]: | 0,5 |
Insulation resist. per 1000 feet [GΩ]: | 0.1524 |
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ]: | 0,5 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ]: | 0.1524 |
Conductor resistance per 1 km [Ω]: | 53 |
Conductor resistance per 1000 ft. [Ω]: | 16.1544 |
Shield. resistance per 1 km [Ω]: | 15 |
Shield. resistance per 1000 ft. [Ω]: | 4.572 |
BPVo-Euroclass: | Cca |
Article number: | 540-0051FC |
---|---|
Name: | Binary 434 DMX512 |
EAN: | 4049371410731 |
Properties: | Analog, Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | ELA 100 V, Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
Application: | DMX |
Colour: | black |
Signal transmission: | symmetrical |
Construction: | [2(2LI2YS0,34mm²)(ST)]CY |
Jacket material: | FRNC |
Jacket Ø [mm]: | 7.00 |
Jacket Ø ["]: | 0.2756 |
Number of Channels (AES/EBU, DMX): | 1 |
Inner conductor (AES/EBU, DMX): | 4 |
Inner conductor (AES/EBU, DMX) [mm²]: | 0,34 |
Inner conductor (AES/EBU, DMX) [sqin]: | 0.0005 |
Inner conductor Ø (AES/EBU, DMX) [mm]: | 0,66 |
Inner conductor Ø (AES/EBU, DMX) ["]: | 0.026 |
AWG (AES/EBU, DMX): | 22 |
Shielding: | Copper-cross mesh, tined + AL / PT foil |
Shielding factor [%]: | 100 |
Copper strands (AES/EBU, DMX): | 7 |
Copper strand Ø (AES/EBU, DMX) [mm]: | 0,25 |
Copper strand Ø (AES/EBU, DMX) ["]: | 0.0098 |
Conductor insulation material: | PE |
Conductor insulation Ø [mm]: | 1,70 |
Conductor insulation Ø ["]: | 0.0669 |
Weight per 1 m [g]: | 65 |
Weight at 1000 ft. [lbs]: | 43.7395 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,22 |
Style variant: | round |
Packing: | 100 m spool |
Temperature min. [°C]: | -15 |
Temperature max. [°C]: | 80 |
Width [mm]: | 7 |
Width ["]: | 0.2756 |
Height [mm]: | 7 |
Height ["]: | 0.2756 |
Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF]: | 58 |
Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF]: | 17.6784 |
Capac. cond./shield. per 1 m (AES/EBU, DMX) [pF]: | 100 |
Capacity wire/electic screen at 1 ft. (AES/EBU, DMX) [pF]: | 30.48 |
Impedance [Ω]: | 110 |
Insulation resist. per 1 km [GΩ]: | 0,5 |
Insulation resist. per 1000 feet [GΩ]: | 0.1524 |
Insulation resist. per 1 km (AES/EBU, DMX) [GΩ]: | 0,5 |
Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ]: | 0.1524 |
Conductor resistance per 1 km [Ω]: | 53 |
Conductor resistance per 1000 ft. [Ω]: | 16.1544 |
Shield. resistance per 1 km [Ω]: | 15 |
Shield. resistance per 1000 ft. [Ω]: | 4.572 |
BPVo-Euroclass: | Cca |
Binary 434 DMX512
DMX
Advantages:
- Digital transmission over long distances due to the DMX and AES/EBU standards
- Excellent protection against electric interference (Cu mesh screen + AL/PT foil)
- Extremely robust due to the special tough jacket
Application:
- Networking of scanners and lighting systems with check-back function
- Connection of digital control units and devices of all kinds
Technical Data:
- Article number: 540-0051FC
- Name: Binary 434 DMX512
- EAN: 4049371410731
- Properties: Digital 110 Ω AES / EBU
- Properties: OFC oxygen free copper
- Properties: Analog
- Application area: ELA 100 V
- Application area: Stage / live
- Application area: Installation
- Application area: Mobile outdoor / indoor
- Application area: Studio / Broadcast
- Application: DMX
- Colour: black
- Signal transmission: symmetrical
- Construction: [2(2LI2YS0,34mm²)(ST)]CY
- Jacket material: FRNC
- Jacket Ø: 7.00 mm
- Jacket Ø: 0.2756 "
- Number of Channels (AES/EBU, DMX): 1
- Inner conductor (AES/EBU, DMX): 4
- Inner conductor (AES/EBU, DMX): 0,34 mm²
- Inner conductor (AES/EBU, DMX): 0.0005 sqin
- Inner conductor Ø (AES/EBU, DMX): 0,66 mm
- Inner conductor Ø (AES/EBU, DMX): 0.026 "
- AWG (AES/EBU, DMX): 22
- Shielding: Copper-cross mesh, tined + AL / PT foil
- Shielding factor: 100 %
- Copper strands (AES/EBU, DMX): 7
- Copper strand Ø (AES/EBU, DMX): 0,25 mm
- Copper strand Ø (AES/EBU, DMX): 0.0098 "
- Conductor insulation material: PE
- Conductor insulation Ø: 1,70 mm
- Conductor insulation Ø: 0.0669 "
- Weight per 1 m: 65 g
- Weight at 1000 ft.: 43.7395 lbs
- UV-resistant: yes
- Fire load per m: 0,22 kWh
- Style variant: round
- Packing: 100 m spool
- Temperature min.: -15 °C
- Temperature max.: 80 °C
- Width: 7 mm
- Width: 0.2756 "
- Height: 7 mm
- Height: 0.2756 "
- Capac. cond./cond. per 1 m (AES/EBU, DMX): 58 pF
- Capacity wire/wire at 1 ft. (AES/EBU, DMX): 17.6784 pF
- Capac. cond./shield. per 1 m (AES/EBU, DMX): 100 pF
- Capacity wire/electic screen at 1 ft. (AES/EBU, DMX): 30.48 pF
- Impedance: 110 Ω
- Insulation resist. per 1 km: 0,5 GΩ
- Insulation resist. per 1000 feet: 0.1524 GΩ
- Insulation resist. per 1 km (AES/EBU, DMX): 0,5 GΩ
- Insulation resist. per 1000 feet (AES/EBU, DMX): 0.1524 GΩ
- Conductor resistance per 1 km: 53 Ω
- Conductor resistance per 1000 ft.: 16.1544 Ω
- Shield. resistance per 1 km: 15 Ω
- Shield. resistance per 1000 ft.: 4.572 Ω
- BPVo-Euroclass: Cca