Bulk Cables  |  AES/EBU, DMX & Power Combi-Cable AES/EBU Audio



SOMMER CABLE - SC-MONOLITH POWER DMX 4



stagemobilestudioinstallation

analogdigitalOFC



When the lights start to dance...

the show begins! There also is a lot of technology behind this performance, SOMMER Cables play a great role here! The power for the lights and the control signals for the movement must be transmitted through the cables.
Both are paired in a robust cable jacket, providing the input for the light mixing board and other DMX 512-dependent control units.

The SC-MONOLITH POWER DMX has a power infeed with a wire diameter of 3 x 1.5mm and one (SC-MONOLITH 1) or two (SC-MONOLITH 2) or four (SC-MONOLITH 4) DMX 512-cables. With the SC-MONOLITH 4 two DMX-cables can be used for transmission of Intercom signals. Each wire pair is shielded with a tin-plated copper spiral. Both wires are numbered for better identification. The SC-MONOLITH 8 is designed for larger events and has eight cables with return channels (8 x 4 x 0.20 mm).

The power line is equipped with its own PVC-jacket for added safety in compliance with VDE.

Of course the AES/EBU-cable can also be used as a microphone cable or as an infeed cable for active speaker systems.

Now also available with a 3 x 2.5mm power cable (HV-Type)

THE ADVANTAGES:

  • Parallel controls for light mixing boards via power line and DMX-signal via cable
  • Very flexible and enormously treadable due to a jacket made of cotton and viscose
  • Very good paired shielding of the DMX-cables due to tin-plated copper spiral shielding


THE APPLICATION:

  • Controls for DMX-light mixing board (surge impedance of 110 )
  • Analog + digital audio multipair with power supply



TECHNICAL DATA:
Construction[(3LIY1,5mm2)Y+xx(2LI2Y0,25mm2)DY]VLY
Power infeed3 x 1,5 mm2
Jacket, diameter, totalPVC 17,0 mm
AWG23
No. of inner conductors4 x 2 x 0,25 mm2
Diameter power infeed7,0 mm
Diameter data cable3,8 mm
Copper strand per cond., data28 x 0,10 mm
Shielding datacross mesh, tin-plated
Shielding factor (audio)90 %
Temperature rangemin. -30 C
Temperature rangemax. 70 C
Fire load per m1,23 kWh
Weight per 1 m265 g
Jacket colorblack
Packagingper m

ELECTRICAL DATA:
Capac. cond./cond. per 1 m55 pF
Capac. cond./shield. per 1 m110 pF
Cond. resistance per 1 km80 Ohm
Insulation resist. per 1 km> 2 GOhm
Surge impedance, data110 Ohm

ORDER DATA:
Order No.500-0051-4
Rec. priceon request



v2008-JUN-8