Bulk Cables  |  Speaker Cable

multicore



  SOMMER CABLE - SC-ELEPHANT SPM440F



stagemobilestudioinstallationELAHiFi

analogFRNChalogen-freeOFC

PUR MASTER BLEND






When the wires run hot...

The crowd cheers when the speakers get turned up to capacity. Then not only the spirits heat up, but also the cables. Here too the highest of demands are placed on the cable, meaning that the outer cable jacket has to be as thick as elephant skin. It should also be flexible, treadable, easily windable, and of course reusable.
Especially mentioned should be the combi-special cable ELEPHANT SPM4025 for use with woofers and surround systems.
The SPM4025 has a total of 6 wires, 4 for the bass range with a diameter of 4.0 mm² (strand diameter 0.20 mm²) and 2 wires for the high frequency range with a diameter of 2.5 mm² (strand diameter 0.15 mm²). Based on this stranding technique commonly used for HiFi-cables the SPM4025 transmits a crystal clear high frequency range and a clean, dynamic bass signal.

Compare them to other speaker cables. The ELEPHANT will convince you!

Now also available in a halogen-free FRNC-version (Test Type C) and E30!

THE ADVANTAGES:

  • Loss-free transmission due to the special stranding
  • Highly flexible (PVC-version only) and suitable for the stage, easily windable
  • Compatible with common Neutrik-Speakon plug connectors
  • Easy to work with due to good insulation and numbered wiring


THE APPLICATION:

  • Professional PA/sound systems
  • Surround und woofer systems
  • For fixed installation in building technology



TECHNICAL DATA:
Construction(4LIY4.0mm2)Y
Jacket, diameterHM2 (FRNC test type C) 11,0 mm
AWG12
No. of conductors4 x 4 mm2
Jacket material, insulationHM2 (Test type halogen free + flame retardant)
Copper strand per conductor225 x 0,15 mm
Conductor insulation, diameter3,75 mm
Temperature rangemin. -30 °C
Temperature rangemax. 70 °C
Fire load per m0,51 kWh
Weight per 1 m273 g
Packagingper m
Colorblack
Typehalogen free
FRNC test typeTest type C according to VDE0472 part 804 and

ELECTRICAL DATA:
Cond. resistance per 1 km< 4,5 Ohm
Insulat. resistance per 1 km> 5 MOhm
Operation voltagemax. 300 V
Test voltage2 kV

ORDER DATA:
Order No.490-0051-440F
Rec. priceon request



v2008-JUN-8