Bulk Cables  |  Multipair Modulation Cable, Fixed installation, FRNC, Audio [AES/EBU]

balanced, PIMF, solid wire, halogen free + flame resistant , AL-foil + copper braiding overall shielding



SOMMER CABLE - SC-LOGIC MODF 24



installationELA

analogdigitalFRNChalogen-freeOFC



A little stiffer it may well be...

but just as reasonably priced. That is exactly what is expected of a modulation cable made of solid wiring. Based on the simple construction the SC-LOGIC won't cost a lot, but will fulfill all important criteria required for fixed installation: The multipair cable SC-LOGIC guarantees incredibly good electrical data (capacity wire/wire 45 pF/m), excellent overall shielding (copper braiding + aluminum foil), a halogen-free and flame-retardant sleeve in conformance with the highest fire protection class (FRNC-IEC60332.3, Test Type C), and individually insulated and numbered wire pairs.
The advantage of a solid wire cable is that very good damping values and a low capacity may be achieved with relatively simple means, which is very important for the long running distance of these cables.
Please observe that these types of cables are not suitable for mobile application.

THE ADVANTAGES:

  • Available and in stock in a 1- to 32-wire version
  • Very reasonably priced
  • For simultaneous transmission of high quality analog data and data in an AES/EBU format (110 Ohm)
  • Conforms to the highest Fire Protection Class FRNC, accord. to IEC60332.3, Test Type C
  • Very easy to work with


THE APPLICATION:

  • Fixed installation in building technology
  • Transmission of AES/EBU standards in broadcasting



TECHNICAL DATA:
Construction[xx(J-02YS0,57mm)(ST)]CH
Inner conductors24 x 2 x 0,57 mm
Jacket, diameterHM2 (FRNC test type C) 23,6 mm
AWG23/1
Copper strand per conductor1 x 0,57 mm
Conductor insulationFoam PE 1,5 mm
ShieldingCopper braiding 85% + AL-foil (total) and filler strand AWG26 (0,4 mm) + AL-foil (wire pairs)
Shielding factor100 %
Temperature rangeFixed installation min. -30 °C
Temperature rangeFixed installation max. 70 °C
Fire load per m1,53 kWh
Weight per 1 m672 g
Jacket colorgray (RAL 7001)
Packagingper m

ELECTRICAL DATA:
Capac. cond./cond. per 1 m45 pF
Capac. cond./shield. per 1 m86 pF
Cond. resistance per 1 km< 82 Ohm
Insulat. resistance per 1 km2 MOhm
Surge impedance(+/-5 %) 110 Ohm

ORDER DATA:
Order No.100-1156-24
Rec. priceon request



v2008-JUN-8