| Copper strand per cond. (video) | (bare) 0,60 mm |
| AWG | (video) 23/1 |
| Conductor insulation | PE 3,6 mm |
| Shielding (video) | Cu-braiding |
| Shielding factor | 90 % |
| Temperature range | min. -20 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,30 kWh |
| Packaging | per m |
| Matching plug | BNC0.6/3.7, NBNC75BLP7 |
| Matching plug | BNC59 |
| Impedance (video) | (+/- 3 %) 75 Ohm |
| Capac. cond./shield. per 1 m | 67 pF |
| Cond. resistance per 1 km | 150 Ohm |
| Damping per 100 m (20 °C) | 1 MHz: 1,1 dB |
| Damping per 100 m (20 °C) | 5 MHz: 2,5 dB |
| Damping per 100 m (20 °C) | 10 MHz: 3,5 dB |
| Damping per 100 m (20 °C) | 100 MHz: 10,2 dB |
| Damping per 100 m (20 °C) | 270 MHz: 17,0 dB |
| Construction video | LI02YSC12Y0,60mm2 |
| Jacket color | black |